Magnolia 5.7 reached extended end of life on May 31, 2022. Support for this branch is limited, see End-of-life policy. Please note that to cover the extra maintenance effort, this EEoL period is a paid extension in the life of the branch. Customers who opt for the extended maintenance will need a new license key to run future versions of Magnolia 5.7. If you have any questions or to subscribe to the extended maintenance, please get in touch with your local contact at Magnolia.
Messages are stored in the messages
workspace. Each user has its own subnode under the workspace root.
/superuser /0 /1 /peter /2 cleared true id 2 message Revised the abstract. Please review. messageView workflow:workflow messageType WORKITEM sender eric subject Publication request for page /travel/about/careers timestamp 1377865432883 workitemId 1377264630284 /eric /0
The numbered nodes (0, 1, 2 etc.) under the users are the messages. Their node type is mgnl:systemMessage
.
Message properties:
cleared
. Whether the message has been read or not.true
/false
id
. Identifies the message. The message ID is unique inside the user node.message
. Text of the message.messageView
. Message view definition name prefixed by the name of the module where the view is configured.messageType
. INFO, WORKITEM, WARNING or ERROR. Defined in MessageType .sender
. Name of the sending user.subject
. Subject line.timestamp
. Time when the message was sent.workItemId
. For workflow messages, an ID of the workitem.